Purity, formulations and chromatography
Pure substances melt at a sharp temperature, and chromatography separates mixtures using Rf values.
Pure and impure
A pure substance is a single element or compound. A Formulation A mixture that has been designed to give a product a specific useful purpose. is a designed mixture with a useful purpose, such as a medicine or paint, and it is not impure in the same sense.
Melting point test
A pure substance melts at a sharp, fixed temperature. An impure substance melts over a range of temperatures, and it starts melting at a lower temperature.
Rf value Rf value (no units)=distance moved by the spot (cm)distance moved by the solvent front (cm)- Baseline
- the line where the sample spot is placed
- Solvent front
- the highest point the solvent reaches
Both distances are measured from the baseline where the spot was placed.
Chromatography
In paper Chromatography A technique for separating the substances in a mixture by how far each moves over a surface., the substances in a mixture travel different distances with the solvent. A substance that dissolves more readily in the solvent moves further.
Rf values
Rf = distance moved by the spot / distance moved by the solvent front. Rf values are between 0 and 1, and they identify a substance when the conditions are the same.
Key terms
- Formulation
- A mixture that has been designed to give a product a specific useful purpose.
- Chromatography
- A technique for separating the substances in a mixture by how far each moves over a surface.
- Rf value
- The distance moved by a spot divided by the distance moved by the solvent front. It has no units.
Check yourself
Which key term means this? The distance moved by a spot divided by the distance moved by the solvent front. It has no units.
Worked example
A spot moves 2.0 cm and the solvent front moves 5.0 cm. Calculate the Rf value. [2 marks]
- 1Rf = 2.0 / 5.0.
- 2= 0.4
The answer: The Rf value is 0.4.
The classic mistake
True or false?
Rf = distance moved by the spot / distance moved by the solvent front.
Wrong: Rf = distance moved by the solvent / distance moved by the spot.
Right: Rf = distance moved by the spot / distance moved by the solvent front.
Exam tip
Command word
Calculate
Measure both distances from the baseline, not from the edge of the paper, and give the Rf value without units.
Try one
Which statement is true for a pure substance?
Test yourself
Try it from memory
Explain the topic in your own words and see what you remember.